Engineered Solutions
By Flow-Tech Industries

Offers a variety of engineered systems for On & Off shore application

TM Series Cooling Towers - By Delta Cooling Towers, Inc.
Premier Series Cooling Towers - By Delta Cooling Towers, Inc.
Anto-Microbial Tower - By Delta Cooling Towers, Inc.
Fire Pump Systems: - By Aurora, Fairbanks, and Layne-Vertiline
Fuel Monitoring Systems: - At engine or through Satellite - By Flow-Tech Industries
Frac Water: Produced Water Treatment System - By Ecologix Systems

Flow-Tech can meet your needs with engineered products customized to product solutions to your unique challenges.

Click to reveal more about each Flow-Tech Engineered Solution:

 

TM Series Induced Draft Towers

TM Series™ Cooling Towers

Delta's TM Series™ induced draft, counter flow design are available in single unit capacities from 250 to 2,000 cooling tons. Manufactured since 2001, the TM Series™ has been very well received in both commercial and industrial applications. The modular cooling tower design allows isolation of cells for operational flexibility.

Click here for TM Sizing Table


TM Series™ Cooling Towers

Standard Features:

  • Seamless Double Wall Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Direct Drive Fan System
  • Totally Enclosed VFD Rated Motors
  • Factory Assembled for Simple Installation
  • 20 Year Shell Warranty
  • PVC Water Distribution System with Non-clog Large Orifice Removable Nozzles
  • High Efficiency PVC Fill
  • Made in the USA

Basic Specs

Detailed Features

All Delta Cooling Towers are factory assembled to the fullest extent possible for ease of installation and shipment. The following features are standard to our TM Series™ Induced Draft Cooling Towers:

Shell:
Shell is seamless, double wall, non-corroding, hi-impact high-density polyethylene (HDPE) of leak proof design. Conical transition for motor/fan assembly with separate polyethylene velocity recovery stacks. The shell exceeds ¼" average thickness. The structural shell is capable of withstanding water temperatures up to 160°F on a continual basis. Between equidistant vertical ribs along the walls are pre-contoured sections that when coupled with the structural foam between the double walls, creates a pre-stressing that adds rigidity and overall structural strength of each cell.

Sump:
Sump is seamless, double wall, non-corroding, hi-impact high-density polyethylene (HDPE) of leak proof design. Sump will be sloped toward outlet. Integral molded-in I-Beam support pockets allow placement on elevated I-Beams. Integral support posts 360° around sump give support to upper tower section and allows mounting of louvered inlet panels for optimum air distribution

Sloped "Clean" Sump Design:
Each cell's sump is molded to slope aggressively towards the center and a 3% slope towards a depressed sump box near the outlet. This limits settlement of any dirt, debris, or biological films and allows for complete drainage of the sump during planned shutdowns.

Water Distribution System:
Totally enclosed, non-corroding, polyvinyl chloride (PVC) pipe with large orifice non-clog spray nozzle distribution system. Threaded nozzle orifices shall be interchangeable allowing substitution of larger diameter orifices for increased flow conditions without increasing inlet pressure.

Wet Decking:
Rigid PVC film, corrugated and bonded for maximum cooling efficiency.

Fan Assembly:
The fan assembly consists of a fan ring, propeller, motor and guard. The fan ring is coated with premium plasite coating ideal for the harshest corrosive environments. An adjustable pitch propeller fan, fiberglass reinforced polypropylene with a silica alloy hub, is directly driven by a totally enclosed VFD Premium rated motor designed for cooling tower duty. A fan guard is included on the velocity recovery stack, and allows protection from the propeller and access to the motor.

Motor:
Totally enclosed air over (TEAO) VFD rated motor with 1.15 service factor, designed for 208 or 230/460V 3 phase 60 cycle operation and suitable for outdoor service. Motor is provided with a 5-year motor manufacturers warranty. 

Fitting Connections:
PVC fittings are provided for inlet, outlet, overflow, drain and make-up connections at standard orientation locations. Orientation for special requirements is available for new and replacement installations.

Hardware:
All fasteners are standard 304 stainless steel. Anchor and lifting lugs are aluminum.

Cutaway View

 

1 - Lightweight And Double Wall: Plastic is lighter than conventional cooling towers and integrated double-wall is more than 10 teims the average wall thickness of metal towers

2 - Leak Proof Sump: Molded as Unitary (One-Piece) Structure that has no joints to leak or require recaulking and sealing

3 - Self Supporting Plastic Base: Tower can be set on flat surface or on I-Beams placed in Integrally-Molded I-Beam Pockets for elevated installations

4 - Corrosion-Proof Shell: HDPE lastic Construction can not corrode and is backed by 15 Year Warranty

5 - Drift Eliminator: Three pass PVC drift eliminator prevents water droplets from leaving the tower

6 - Nozzle Water Distribution System: Non-Clog large crifice removable nozzles evenly distribute the water

7 - Fill Material: High efficiency PVC cellular design for maximum cooling

8 - Direct Drive Air Moving System: Totally enclosed VFD rated cooling tower motors power multiple fiber-reinforced polyproplene axial propleller fans within a polyethylene velocity recovery stack

Downloads

TM Installation & Operating Manual PDF
TM Specification PDF
(1) One cell Plan & Elevation drawing PDF
(2) Two Cell (3, 5, & 7.5 HP) Plan & Elevation drawing PDF
(2) Two Cell (10 & 15 HP) Plan & Elevation drawing PDF
(3) Three Cell Plan & Elevation drawing PDF
(3) Three Cell Side View & Detail drawing PDF
(4) Four Cell Plan & Elevation drawing PDF
(4) Four Cell Side View & Detail drawing PDF
(5) Five Cell Plan & Elevation drawing PDF
(5) Five Cell Side View & Detail drawing PDF
(6) Six Cell Plan & Elevation drawing PDF
(6) Six Cell Side View & Detail drawing PDF

 

Premiere Induced Draft Tower

Premier™ Cooling Towers

Delta's Premier™ induced draft, counter flow, low profile cooling tower design is available in single module capacities from 250 to 500 cooling tons.

These towers use the same unitary seamless engineered plastic construction that Delta has been manufacturing since 1997, and have been very well received in both commercial and industrial applications.

Premier's cost less to install and operate!  The light weight construction reduces rigging and structural roof support requirements. While maintenance and water treatment chemical costs are significantly lowered.

Standard Features:

  • Seamless Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Coated Steel Mounting Platform
  • Direct Drive Fan System
  • Totally Enclosed VFD Rated Motors
  • Completely Factory Assembled
  • 20 Year Shell Warranty
  • PVC Water Distribution System with Non-clog Large Orifice Removable Nozzles
  • High Efficiency PVC Fill
  • Made in the USA

All Delta Cooling Towers are factory assembled to the fullest extent possible for ease of installation and shipment. The following features are standard on our Premier™ Series Induced Draft Cooling Towers:

Shell:
A seamless engineered polyethylene (HDPE) molded shell, with conical transition for motor/fan assembly and integrally molded louvered inlet section around base of cooling tower integrated for optimum air distribution. There are no joints, seams, panels, gaskets, bolts, fasteners or caulking like conventional towers. 

Sump:
Sump is integral with cooling tower shell, creating a one-piece seamless structure. 

Water Distribution System:
A self propelled PVC distribution system incorporating a rotating sprinkler head and lateral distribution arms with integral drift eliminators. An inspection port is provided in the cooling tower shell at the lateral arm elevation for adjustment.

Wet Decking:
Non-corrosive, polyvinyl chloride (PVC) wet decking, bonded and packed for maximum film cooling efficiency.

Fan Assembly:
The fan assembly consists of a fan ring, propeller, motor and guard. The fan ring is coated with premium plasite coating ideal for the harshest corrosive environments. An adjustable pitch propeller fan, fiberglass reinforced polypropylene with a silica alloy hub, is directly driven by a totally enclosed VFD Premium rated motor designed for cooling tower duty. A fan guard is included that allows protection from the propeller and access to the motor.

Motor:
Totally enclosed air over (TEAO) VFD rated motor with 1.15 service factor, designed for 208 or 230/460V 3 phase 60 cycle operation and suitable for outdoor service. Motor is provided with a 5-year motor manufacturers warranty. 

Fitting Connections:
PVC fittings are provided for inlet, outlet, overflow, drain and make-up connections at standard orientation locations. Orientation for special requirements is available for new and replacement installations.

Hardware:
All fasteners are 304 stainless steel. Anchor and lifting lugs are aluminum

Cutaway View

Downloads

Premier Manual PDF
Premier Specification PDF
TR-205812 Thru TR-210812 Assembly PDF
TR-305812 Thru TR-310812 Assembly PDF

 


Anti-Microbial Cooling Tower

Tower Shell

  • Anti-Microbial HDPE Resin
  • Fully Compounded Throughout Resin
  • Resists Biofilm Growth
  • Withstands Most Aggressive Chemical Treatments

Tower Fill & Drift Eliminator

  • Anti-Microbial Compounded PVC or PP
  • Impedes Microorganism Growth
  • Prevents Fouling Maximizing Performance
  • Resists Biofilm Growth

Introducing our NEW Anti-Microbial (AM) Cooling Tower. According to test results from Special Pathogens Laboratory®, The Legionella Experts®, our tower displays the only Anti-Microbial efficacy against Legionella bacteria out of all the common cooling tower materials.

Legionnaire's Disease

What is Legionnaire's Disease?

A harmful lung infection caused by the bacteria Legionella. This bacteria grows best in warm water conditions where it is spread to humans when water vapor or mist containing the bacteria is inhaled. Cooling towers have an ideal environment for this growth.

Grow Promotion

  • Poor water flow and areas where water is stagnant, common to cooling tower designs with a large flat bottom basin, which will have stagnant water in the corners.
  • pH between 5.0 and 8.5, water temperatures between 68°F and 122°
  • Sediment that promote growth of commensal microflora
  • Microorganisms including algae, flavobacteria, and Pseudomonas, which supply essential nutrients for Legionella growth or harbor the organism

Prevention

  • Chemical Water Treatment: Oxidizing Biocides are recommended as the best mode of control. Warning: this type of biocide can be aggressive towards metal surfaces; specifically metal cooling towers.
  • System Design & Engineering: No stagnant water, sloped basin, and/or basin sweeper system.
  • Maintenance – Competent consistent water treatment and monitoring most important.

According to the Center for Disease Control and Prevention, about 5,000 cases of Legionnaire's disease are now reported each year in the United States.

Delta Anti-Microbial (AM) Cooling Tower

graphic

We begin manufacturing with anti-microbial resin, which is fully compounded into base cooling tower plastic material. Our anti-microbial additives operate on the cellular level to continuously disrupt and prevent uncontrolled growth of the microorganisms and biofilm.

The blue colored cooling towers are a clear sign to the industry that they are antimicrobial; therefore substantially reducing the risk of harmful cooling tower-borne pathogens, such as Legionnaire's Disease.

 

Test Results

The bacteria tested were Legionella Pneumophila Serogroup 1. The base materials tested were Delta Compounded HDPE, FRP, and Stainless Steel and the numbers reflect bacterial count after 24 hour incubation.

Tower Design Minimizes Legionella Risk

  • Aggressive Slope Side to Side
  • 3% Slope Back to Outlet
  • Basin Sweeper System on Some Models

Stagnant Water is a breeding ground for microorganisms which reproduces Legionella. Our design prevents stagnant water.

Downloads

Delta Cooling Anti-Microbial Tower Brochure PDF
Anti-Microbial Tower - Frequently Asked Questions PDF
Delta Cooling Towers Anti-Microbial Press Release PDF

Fire Pump Systems (UL/FM) Listed

Fuel Monitoring Systems

Engineered Systems - Fuel Monitoring 1Engineered Systems - Fuel Monitoring 2Engineered Systems - Fuel Monitoring3Engineered Systems - Fuel Monitoring 4Engineered Systems - Fuel Monitoring 5

 

Flow-Tech custom designs fuel monitoring around customer needs.
Specializing in the Marine and offshore oil and gas markets, we can offer the simplest tasks of retrieving information at the engine or in control room / wheel house, or the complicated task of having information sent by Satellite to the home office.

 

Frac Water Reclamation

Integrated Treatment System

High-rate Flowback and Produced Water Treatment System Engineered For Solids Separation Efficiency

System Features

  • Mobile Frac Tank Chassis
  • Multi-stage Chemical Mixing
  • Dissolved Air Flotation Vessel
  • Corrosion Resistant Coatings
  • Complete Automation

Operational Benefits

  • Process up to 900GPM / 31,000BBL/DAY
  • TSS Reduction up to 99.9%
  • FOG Reduction up to 99.9%
  • Rapid Deployment / Start-Up

View PDF


For more information about PPC Mechanical Seals, call our main number at 713.690.7474. You can also contact a Flow-Tech sales representative via e-mail at sales@flow-tech.com.


Houston
Corporate Headquarters
4601 South Pinemont, Suite 100 Houston, Texas 77041

Phone: 713.690.7474
Fax: 713.690.7979
Other Locations
Beaumont, TX
Lake Charles, LA

E-mail: sales@flow-tech.com
Site Map

Follow Us on Facebook Follow Us on Twitter View Us on Youtube